AAAC 400 mm2 Conductor Cable-All Aluminium Alloy Conductor

Cable AAAC

Contact Us

AAAC 400 mm2 Conductor Cable All Aluminium Alloy Conductor

What is AAAC 400 mm2 Conductor Cable?

AAAC 400 mm2 Conductor Cable is mainly used as uninsulated overhead transmission cable and as primary and secondary distribution cable. It is also suitable for installation in water bodies such as basins, rivers and valleys with unique geographical conditions.

The wire AAAC driver of 400 mm2 is manufactured using heat-treatable aluminum-magnesium alloys that comply with relevant international standards. The electrical and mechanical properties of these alloys align with the specified standards. Besides, conductors meeting other recognized specifications may be provided. Although these alloys have greater strength compared to pure aluminum, They have lower conductivity. Due to its lower weight, alloy conductors may be advantageous over ACSR cables (steel reinforced aluminum conductor) traditional, especially when ice and wind loads are minimal, despite their lower breaking loads.

AAAC Standard 400 mm2 Conductor Cable

Aluminum alloy cables (6201 T81) are concentrically twisted.

IEC 61089 Overhead stranded electrical conductors with concentric laying of round cables

AAAC Technical Data 400 mm2 Conductor Cable

Nominal areaBraiding number diameterCalculated areaTotal diameterResistance D,C.Calculated breaking loadCalculated weight
mm2No. mmmm2mmOh/km Nkg/km
40037/3.71399.9825.970.08370111.711102.3

AAAC Applications 400 mm2

The AAAC cable 400 mm² has a wide range of applications in electrical distribution systems due to its superior properties, such as its high resistance and low weight thanks to the aluminum alloy used. Here we detail how it is used in different areas.:

AAAC Cable Applications 400 mm²:

Primary and Secondary Distribution: This type of cable is frequently used in electrical networks to transmit energy at both primary and secondary levels., in both urban and rural environments. Its robust and lightweight design makes it easy to handle and deploy.

Overhead Transmission Lines: The AAAC 400 mm² is ideal for overhead power transmission lines, especially in medium and high voltage configurations. Its resistance to heavy loads and adverse weather conditions makes it suitable for this type of applications..

Electrical substations: It is also used in electrical substations to connect transformers and other equipment.. Its high resistance and ability to withstand mechanical and thermal stress make it suitable for connections between equipment in these installations..

Advantages of AAAC Cable 400 mm²:

High Resistance: The aluminum alloy used in the cable provides superior resistance to corrosion and harsh atmospheric conditions.
Lightness: Lightweight design makes installation and handling easier compared to cables made from heavier materials.
Durability: Provides long life in demanding conditions, reducing the need for frequent replacements.