Cable ACSR Bittern 1272MCM
What is ACSR Bittern 1272MCM Cable?
ACSR Bittern 1272MCM Cable is a specific type of conductor cable used in electrical power transmission systems. The designation “ACSR” means “Aluminum Conductor Steel Reinforced” (Aluminum Conductor with Reinforced Steel Core), which indicates that it is composed of a steel core surrounded by aluminum wires. “Bittern” is the name assigned to this particular type of driver, while “1272MCM” is the measure of its cross-sectional area.
ACSR Bittern 1272MCM Cable Standard
ASTM B-230 aluminum wire, 1350-H19 for electrical purposes
ASTM B-231 Aluminum Conductors, concentric braids.
ASTM B-232 Aluminum Conductors, concentrically laid braids, reinforced with coated steel (ACSR)
ASTM B-341 Aluminum Coated Steel Core Wire for Aluminum Conductors, reinforced with steel (ACSR/AZ)
ASTM B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, reinforced with steel (ACSR)
Technical data of Cable ACSR Bittern 1272MCM
Key name | Area | Braiding and diameter | Approximate overall diameter | linear mass | Nominal tensile strength | D.C. Resistance to 20 ℃ Ω/km | ||||||
Aluminum | Steel | Total | Aluminum | Steel | Aluminum | Steel | Total. | |||||
AWG or MCM | mm2 | mm2 | mm2 | mm | mm | mm | kg/km | kg/km | kg/km | andN | ||
Bittern | 1272.00 | 644.51 | 44.52 | 689.03 | 45/4.27 | 7/2.85 | 34.17 | 1785.0 | 349 | 2134 | 15148 | 0.04494 |
Bittern 1272MCM Applications
Bittern 1272MCM has been designed to meet the demands of electrical transmission in high capacity applications. With its cross-sectional area of 1272 circular thousands thousand, This cable can carry large electrical loads efficiently over long distances.
The design of the ACSR (Aluminum Conductor Steel Reinforced) combines the excellent electrical conductivity of aluminum with the mechanical resistance provided by the steel core. This allows the cable to withstand significant electrical and mechanical stresses without compromising its structural integrity..
In terms of applications, The Bittern 1272MCM is ideal for use in high voltage electrical power transmission systems, especially in areas where considerable load capacity and reliable tensile strength are required. Its robust design makes it suitable for a variety of environments, from urban areas to rural or mountainous regions.
In summary, The Bittern 1272MCM has been designed with adequate load capacity and structural strength to meet the electrical transmission needs in high capacity and mechanically demanding applications..