35kV ACSR 3 tree wire layers

ACSR 2 tree wire layers

Contact Us

35kV ACSR Tree Wire

What is 35kV ACSR Tree Wire?

35kV ACSR Tree Wire are concentrically stranded conductors, which come in compressed or compact formats depending on their size. These conductors can be insulated with high-density track resistant polyethylene (HDTRPE) road-resistant cross-linked polyethylene (XLPE) to adapt to various needs and applications.

35kV Standard ACSR Tree Wire

ASTM B230/B231M – Standard Specification for 1350-H19 Aluminum Cables for Electrical Purposes
ASTM B232/B232M – Standard Specification for Concentrically Stranded Aluminum Conductor Reinforced with Clad Steel (ACSR)
ASTM B398/B399M – Standard Specification for 6201-T81 Aluminum Alloy Cables for Electrical Purposes
ASTM B400 – Standard Specification for Aluminum Conductor 1350 compact round concentric braiding
ICEA S-121-733 – Standard for spacer cables supported by tree and messenger cables

Technical Data 35kV ACSR Tree Wire

Size (AWG o kcmil)StrandingConductor diameter (mils)Cover thickness (mils)Cable outer diameter (mils)Nominal resistance (lbs)Weight per 1000 pies.(lbs)
conductive shieldinner layerOuter layer
1/06/13981517512510284161448
2/06/14471517512510775045509
4/06/15631517512511937933673
266.818/16091517512512396536684
266.826/764215175125127210735770
336.418/16841517512513148246794
336.426/772015175125135013395901
336.430/7741151751251371164351170
397.518/17431517512513739443889
397.524/777215175125140213870949
397.526/7783151751251413154851013
47724/7846201751251486163401091
47726/7858201751251498185251168
47730/7883201751251523226101552
556.518/1879201751251519130151138
556.524/7914201751251554188101220
556.526/7927201751251567214701309
63618/1940201751251580149151637
63626/7990201751251630239401826
79526/71107201751251747299252146
79545/71063201751251703209951892

Tree Wire Applications

35kV ACSR Tree Wire Used for primary and secondary aerial distribution in scenarios where space must be conserved or where narrower rights-of-way are preferred. Its installation mirrors that of bare conductors, but its cover serves as crucial protection against direct short circuits and instantaneous discharges with nearby objects. Proximity design reduces space and hardware required for line installation, which is especially beneficial in densely populated areas such as alleys or narrow passages.

    Request a free quote, we will answer you in 24 hours.

    Your e-mail*:

    Your name*:

    Your country:

    Your telephone*:

    Your message*: