Cable SAC 15kV 25kV 35kV

SAC CABLE

Contact Us

CABLE SAC 15kV-25kV-35kV

SAC Cable Application

Cable Sac 15kV-25kV-35kV, Stranded cross-linked aluminum conductor, spaced polyethylene sheathed aerial cable, for use on primary aerial cable on pole.

SAC Cable Standard

ICEA S-66-524 / THING / PEA

SAC Cable Construction

Conductor: Compact Hard Braided Aluminum Wire.
conductor shield: Semiconductor cross-linked polyethylene.
Isolation: cross-linked polyethylene (Natural).
Funda: Rail resistant cross-linked polyethylene (Negro).

Technical data of SAC 15kV Cables

Nominal
Sectional
Area
mm²
Minimum
Number
of wire
NO
Diameter
of
Conductor
(approx.)
mm
Thickness
of
Isolation
mm
Thickness
sling
mm
In general
Diameter
(approx.)
mm
Maximum
DC
conductor
endurance
a 20 ºC
Oh/km
Minimum
isolation
endurance
a 15,6 ºC
MΩ – km
In general
Diameter
(approx.)
mm
Cable
weight
(approx.)
kg/km
2565.901.911.9115.01.2002019.00120.00194.00
3566.951.911.9116.00.8681820.00151.00232.00
5068.331.911.9117.50.6411612.00187.00291.00
70129.731.911.9119.00.4431445.00231.00358.00
951511.451.911.9121.00.3201284.00281.00451.00
1201512.951.911.9122.50.2531152.00324.00552.00
1501514.271.911.9124.00.2061070.00375.00639.00
1853015.981.911.9125.50.164980.00433.00763.00
2403018.471.911.9128.00.125874.00525.00953.00

Technical data of SAC 25kV Cables

Nominal
Sectional
Area
mm²
Minimum
Number
of wire
NO
Diameter
of
Conductor
(approx.)
mm
Thickness
of
Isolation
mm
Thickness
sling
mm
In general
Diameter
(approx.)
mm
Maximum
DC
conductor
endurance
a 20 ºC
Oh/km
Minimum
isolation
endurance
a 15,6 ºC
MΩ – km
In general
Diameter
(approx.)
mm
Cable
weight
(approx.)
kg/km
2565.903.1753.17520.01.2002827.00119.00317.00
3566.953.1753.17516.00.8682580.00149.00363.00
5068.333.1753.17517.50.6412314.00186.00432.00
70129.733.1753.17519.00.4432100.00229.00509.00
951511.453.1753.17521.00.3201887.00279.00615.00
1201512.953.1753.17522.50.2531712.00321.00729.00
1501514.273.1753.17524.00.2061600.00371.00826.00
1853015.983.1753.17525.50.1641477.00429.00959.00
2403018.473.1753.17528.00.1251328.00520.001170.00

Technical data of SAC 35kV Cables

Nominal
Sectional
Area
mm²
Minimum
Number
of wire
NO
Diameter
of
Conductor
(approx.)
mm
Thickness
of
Isolation
mm
Thickness
sling
mm
In general
Diameter
(approx.)
mm
Maximum
DC
conductor
endurance
a 20 ºC
Oh/km
Minimum
isolation
endurance
a 15,6 ºC
MΩ – km
In general
Diameter
(approx.)
mm
Cable
weight
(approx.)
kg/km
2565.904.4453.17522.51.2003153.00118.00393.00
3566.954.4453.17524.50.8682890.00148.00443.00
5068.334.4453.17525.50.6412606.00184.00517.00
70129.734.4453.17527.50.4432375.00227.00599.00
951511.454.4453.17529.00.3202144.00276.00711.00
1201512.954.4453.17531.00.2531952.00318.00831.00
1501514.274.4453.17532.50.2061830.00367.00933.00
1853015.984.4453.17533.50.1641694.00425.001073.00
2403018.474.4453.17536.50.1251529.00515.001293.00

    Request a free quote, we will answer you in 24 hours.

    Your e-mail*:

    Your name*:

    Your country:

    Your telephone*:

    Your message*:

    Floating Social Media Icons by Acurax Wordpress Designers