4/0-4/0-2/0 Cerapus Aluminum XLPE Triplex Aerial Service Drop Cable
What is the 4/0-4/0-2/0 Cerapus aluminio XLPE Cable triplex bajada de servicio aéreo?
4/0-4/0-2/0 Cerapus aluminio XLPE Cable triplex bajada de servicio aéreo es un producto diseñado para aplicaciones eléctricas aéreas. Este cable se utiliza comúnmente para suministrar servicios temporales de 120 volts on construction sites, outdoor or street lighting. Besides, is capable of handling services up to 600 volts or less, with a maximum conductor temperature of 90°C.
Due to its driver size and technical characteristics, the wire 4/0-4/0-2/0 Cerapus es una opción confiable y segura para una variedad de aplicaciones residenciales, commercial and industrial. Its strength and durability make it a popular choice for efficient and safe electrical distribution in different environments..
4/0-4/0-2/0 alambre de aluminio cerapus triplex XLPE, 4/0-4/0-2/0 alambre aéreo cerapus triplex XLPE, 4/0-4/0-2/0 cerapus triplex de aluminio XLPE, Conductor triplex cerapus 4/0-4/0-2/0 XLPE, alambre aéreo de aluminio cerapus 4/0-4/0-2/0 XLPE, cables aéreos de aluminio cerapus 4/0-4/0-2/0 XLPE, Conductores de bajada de servicio aéreo cerapus 4/0-4/0-2/0 XLPE.
Standard of 4/0-4/0-2/0 Cerapus Aluminum XLPE Triplex Aerial Service Drop Cable
ASTM B-230: Standard Specification for Aluminum Conductors (aluminum 1350) con temple.
ASTM B-231: Standard Specification for Concentric Conductor Aluminum Cable.
ASTM B-232: Standard Specification for Reinforced Steel Alloy Aluminum and Aluminum Conductors (AAC, ACSR).
ASTM B-399: Standard Specification for 6201-T81 Aluminum Conductor.
ICEA S-76-474: International Electrical and Electronic Cable Engineering Association Standard for Low Voltage Overhead Power Cables.
Technical data of 4/0-4/0-2/0 Cerapus Aluminum XLPE Triplex Aerial Service Drop Cable
Phase Conductor Size: 4/0 AWG
Number of Phase Conductor Wires: 19
Insulation Thickness: 0.060 inches
Neutral Conductor Size: 2/0 AWG
Number of Neutral Conductor Wires: 6/1
Allowable Amperage Rating: 300 Amps
Weight: 0.678 pounds per foot
Aplicaciones del Cable
4/0-4/0-2/0 Inspección Inicial:
Before installation, Visually inspect the cable to ensure it has no visible damage, like cuts, abrasions or deformations.
Cable Measurement and Cutting:
Measure the required cable length, taking into account the route and possible curves.
Cut the cable to the desired length using appropriate cutting tools.
Cable Installation:
Attach cable securely to posts or structures using appropriate clamps and fasteners.
Security and Maintenance:
Make sure the cable is free of obstructions and not exposed to mechanical damage.
Perform periodic inspections of the cable and connections to ensure they are in good condition and functioning.
Following these installation instructions, will ensure safe and efficient installation of aluminum triplex overhead service drop cable.