1/0-1/0-1/0-2 Notre Dame Aluminum XLPE URD Quadruplex Direct Burial Cable
What is 1/0-1/0-1/0-2 Notre Dame Aluminum XLPE URD Quadruplex Direct Burial Cable?
1/0-1/0-1/0-2 Notre Dame Aluminum XLPE URD Quadruplex Direct Burial Cable is an underground electrical cable that is also used as a service entrance cable and for wiring underground secondary circuits. This cable has four gauge conductors 1/0 AWG. Three of these conductors correspond to the phases of a three-phase system, and the fourth driver, that has yellow stripes, acts as the neutral conductor. It is a medium duty cable, with a temperature rating of 90°C and a voltage rating of 600 volts. Its current capacity is 120 amps when directly buried and 85 amps when installed in ducts.
Also know as: 1/0-1/0-1/0-2 urd aluminum cable our XLPE, 1/0-1/0-1/0-2 notre urd XLPE direct burial cable, 1/0-1/0-1 /0-2 our XLPE quadruplex cable, 1/0-1/0-1/0-2 our XLPE quadruplex cable, 1/0-1/0-1/0-2 our four conductor XLPE cable, 1/0-1/0 -1/0-2 our four conductor XLPE cable, 1/0-1/0-1/0-2 our XLPE direct burial electrical cable, 1/0-1/0-1/0-2 our XLPE direct burial power cable, 1 /0-1/0-1/0-2 XLPE direct burial aluminum cable.
Standard of 1/0-1/0-1/0-2 Notre Dame Aluminum XLPE URD Quadruplex Direct Burial Cable
ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W
Technical data 1/0-1/0-1/0-2 Notre Dame Aluminum XLPE URD Quadruplex Direct Burial Cable
Phase conductor size AWG 1/0
Stranding of the phase conductor 9
Phase conductor insulation thickness 80 Mls
AWG Base Neutral Messenger Size 2
Base Neutral Braid 7
Single phase conductor diameter (thousandths of an inch) 512
Full cable diameter (external diameter) (thousandths of an inch) 1236
Weight for each 1000 feet in total (pounds) 534
Allowable amperage at 90 °C (amps) 200
Admissible amperage in ducts (amps) 150
URD Cable Applications
1/0-1/0-1/0-2 Notre Dame Cable URD has a rated current capacity that depends on several factors, including ambient temperature, installation and specific conditions of use. However, los 1/0-1/0-1/0-2 Notre Dame Cable typically have a fairly high current capacity due to their thickness and design..
The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..