2/0-2/0-2/0 Hunter Aluminum XLPE URD Triplex Direct Burial Cable
What is 2/0-2/0-2/0 Hunter Aluminum XLPE URD Triplex Direct Burial Cable?
2/0-2/0-2/0 Hunter Aluminum XLPE URD Triplex Direct Burial Cable It is intended for use in secondary distribution circuits, being suitable for installation in conduits or for direct burial applications. Maximum operating temperature should not exceed 90°C in wet and dry locations. The nominal voltage is 600 volts. As an option, This cable can be delivered pre-installed in conduit.
Also know as: Hunter aluminum urd cable 2/0-2/0-2/0 XLPE, Urd Hunter direct burial cable 2/0-2/0-2/0 XLPE, Hunter tres 2/0-2/0-2/0 Cable conductor XLPE, Hunter triplex wire 2/0-2/0-2/0 XLPE, cable triplex Hunter 2/0-2/0-2/0 XLPE, Hunter triplex aluminum underground wire 2/0-2/0-2/0 XLPE , 2/0-2/0-2/0 power cord 3 Hunter XLPE conductors, 2/0-2/0-2/0 Hunter XLPE aluminum triplex, 2/0-2/0-2/0 Hunter XLPE underground triplex, 2/ 0-2/0-2/0 triplex hunter XLPE underground cable, 2/0-2/0-2/0 triplex hunter XLPE underground cable, 2/0-2/0-2/0 hunter XLPE direct burial triplex, 2/0- Conductor triplex Hunter 2/0-2/0 XLPE, Hunter Direct Burial Electrical Cable 2/0-2/0-2/0 XLPE, Hunter direct burial power cable 2/0-2/0-2/0 XLPE, 2/0-2 Hunter Aluminum Direct Burial Cable /0-2/0 XLPE.
Standard of 2/0-2/0-2/0 Hunter Aluminum XLPE URD Triplex Direct Burial Cable
ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W
Technical data 2/0-2/0-2/0 Hunter Aluminum XLPE URD Triplex Direct Burial Cable
URD Cable Applications
2/0-2/0-2/0 Hunter Cable URD has a rated current capacity that depends on several factors., including ambient temperature, installation and specific conditions of use. However, los 2/0-2/0-2/0 Hunter Cable URDs typically have a fairly high current rating due to their thickness and design..
The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..