2/0-2/0-2/0-1 Syracuse Aluminum XLPE URD Quadruplex Direct Burial Cable

Quadruplex Cable

Contact Us

2/0-2/0-2/0-1 Syracuse Aluminum XLPE URD Quadruplex Direct Burial Cable

What is 2/0-2/0-2/0-1 Syracuse Aluminio XLPE URD Cuádruplex Cable De Entierro Directo?

2/0-2/0-2/0-1 Syracuse Aluminio XLPE URD Cuádruplex Cable De Entierro Directo es un cable eléctrico subterráneo que también se utiliza como cable de entrada de servicio y para el cableado de circuitos secundarios subterráneos. This cable has four gauge conductors 2/0 AWG. Three of these conductors correspond to the phases of a three-phase system, and the fourth driver, that has yellow stripes, acts as the neutral conductor. It is a medium duty cable, with a temperature rating of 90°C and a voltage rating of 600 volts. Its current capacity is 120 amps when directly buried and 85 amps when installed in ducts.

Also know as: 2/0-2/0-2/0-1 cable de urd de aluminio de Syracuse XLPE, 2/0-2/0-2/0-1 cable de entierro directo de urd de Syracuse XLPE, 2/0-2/0-2 /0-1 cable cuádruplex de Syracuse XLPE, 2/0-2/0-2/0-1 cable cuádruplex de Syracuse XLPE, 2/0-2/0-2/0-1 cable de cuatro conductores Syracuse XLPE, 2/0-2/0 -2/0-1 cable de cuatro conductores de Syracuse XLPE, 2/0-2/0-2/0-1 cable eléctrico de entierro directo de Syracuse XLPE, 2/0-2/0-2/0-1 cable de alimentación de entierro directo de Syracuse XLPE, 2 /0-2/0-2/0-1 Cable de enterramiento directo de aluminio Syracuse XLPE.

Standard of 2/0-2/0-2/0-1 Syracuse Aluminum XLPE URD Quadruplex Direct Burial Cable

ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W

Technical data 2/0-2/0-2/0-1 Syracuse Aluminum XLPE URD Quadruplex Direct Burial Cable

Phase conductor size AWG 2/0
Stranding of phase conductors 11
Thickness Insulation Conductor Phase 80 Mls
Base Neutral Messenger Size AWG 1
Hilo Neutral Base 9
Single phase conductor diameter (mils) 555
Full cable diameter (D.E.) (thousandths of an inch) 1340
Weight per 1000 pies total (pounds) 657
Allowable ampacity 90C (amps) 225
Allowable ampacity in ducts (amps) 170

URD Cable Applications

2/0-2/0-2/0-1 Syracuse Cable URD tiene una capacidad de corriente nominal que depende de varios factores, including ambient temperature, installation and specific conditions of use. However, los 2/0-2/0-2/0-1 Syracuse suelen tener una capacidad de corriente bastante alta debido a su grosor y diseño.

The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..

    Request a free quote, we will answer you in 24 hours.

    Your e-mail*:

    Your name*:

    Your country:

    Your telephone*:

    Your message*:

    Animated Social Media Icons by Acurax Responsive Web Designing Company