2-2-2 Ramapo Aluminum XLPE URD triplex Direct Burial Cable

Triplex URD Cable

Contact Us

2-2-2 Ramapo Aluminio XLPE URD Triplex Cable De Entierro Directo

What is 2-2-2 Ramapo Aluminio XLPE URD Triplex Cable De Entierro Directo?

2-2-2 Ramapo Aluminio XLPE URD Triplex Cable De Entierro Directo It is intended for use in secondary distribution circuits, being suitable for installation in conduits or for direct burial applications. Maximum operating temperature should not exceed 90°C in wet and dry locations. The nominal voltage is 600 volts. As an option, This cable can be delivered pre-installed in conduit.

Also know as: cable urd de aluminio ramapo 2-2-2 XLPE, cable de enterramiento directo ramapo urd 2-2-2 XLPE, cable de tres conductores ramapo 2-2-2 XLPE, cable triplex ramapo 2-2-2 XLPE, cable triplex, 2-2-2 Cable subterráneo de aluminio ramapo triplex XLPE, power cord 3 conductores ramapo 2-2-2 XLPE, triplex de aluminio, triplex subterráneo ramapo 2-2-2 XLPE, cable subterráneo triplex ramapo 2-2-2 XLPE, cable triplex ramapo 2-2-2 subterráneo XLPE, 2-2-2 ramapo triplex de entierro directo XLPE, 2-2-2 ramapo triplex conductor XLPE, 2-2-2 ramapo cable eléctrico de entierro directo XLPE, 2-2-2 ramapo cable de alimentación de entierro directo XLPE, 2-2-2 ramapo de aluminio Cable de enterramiento directo XLPE.

Standard of 2-2-2 Ramapo Aluminio XLPE URD Triplex Cable De Entierro Directo

ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W

Technical data 2-2-2 Ramapo Aluminio XLPE URD Triplex Cable De Entierro Directo

Phase conductor size AWG: 2
Wiring of phase conductors: 7
Phase conductor insulation thickness: 60 ml.
AWG Base Neutral Messenger Size: 2
base neutral hilum: 7
Single phase conductor diameter (mils): 403
Full cable diameter (O.D.) (mil): 870
Total weight per 1000 pies (pounds): 278
Allowable ampacity 90C (amps): 165
Allowable ampacity in ducts (amps): 120

URD Cable Applications

2AWG Ramapo Cable URD tiene una capacidad de corriente nominal que depende de varios factores, including ambient temperature, installation and specific conditions of use. However, los 2 AWG Ramapo suelen tener una capacidad de corriente bastante alta debido a su grosor y diseño.

The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..

    Request a free quote, we will answer you in 24 hours.

    Your e-mail*:

    Your name*:

    Your country:

    Your telephone*:

    Your message*:

    Social Media Integration by Acurax Wordpress Developers