3/0-3/0-1/0 Hollins Aluminum XLPE URD Triplex Direct Burial Cable
What is 3/0-3/0-1/0 Hollins Aluminio XLPE URD Triplex Cable De Entierro Directo?
3/0-3/0-1/0 Hollins Aluminio XLPE URD triplex Cable de Entierro Directo It is intended for use in secondary distribution circuits, being suitable for installation in conduits or for direct burial applications. Maximum operating temperature should not exceed 90°C in wet and dry locations. The nominal voltage is 600 volts. As an option, This cable can be delivered pre-installed in conduit.
Also know as: cable urd de aluminio 3/0-3/0-1/0 hollins XLPE, cable de entierro directo urd 3/0-3/0-1/0 hollins XLPE, 3/0-3/0-1/0 hollins tres Cable conductor XLPE, cable triplex Hollins 3/0-3/0-1/0 XLPE, cable triplex Hollins 3/0-3/0-1/0 XLPE, cable subterráneo de aluminio triplex Hollins 3/0-3/0-1/0 XLPE, 3/0-3/0-1/0 power cord 3 conductores hollins XLPE, 3/0-3/0-1/0 triplex de aluminio hollins XLPE, 3/0-3/0-1/0 triplex subterráneo hollins XLPE, 3/ 0-3/0-1/0 cable subterráneo hollins triplex XLPE, 3/0-3/0-1/0 cable subterráneo hollins triplex XLPE, 3/0-3/0-1/0 triplex de entierro directo hollins XLPE, 3/0- Conductor triplex 3/0-1/0 hollins XLPE, cable eléctrico de entierro directo 3/0-3/0-1/0 hollins XLPE, cable de alimentación de entierro directo 3/0-3/0-1/0 hollins XLPE, 3/0-3 /0-1/0 cable de enterramiento directo de aluminio hollins XLPE.
Standard of 3/0-3/0-1/0 Hollins Aluminum XLPE URD Triplex Direct Burial Cable
ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W
Technical data 3/0-3/0-1/0 Hollins Aluminum XLPE URD Triplex Direct Burial Cable
Phase conductor size: 3/0
Phase conductor insulation thickness: 0,080 inches
Neutral conductor size: 1/0
Espesor del aislamiento del conductor neutro: 0,080 inches
External diameter: 1.276 inches
Allowable ampacity: direct burial: 280 amps
Allowable ampacity: en conducto: 205 amps
Peso por pie: 0,608 pounds
URD Cable Applications
3/0AWG Hollins Cable URD tiene una capacidad de corriente nominal que depende de varios factores, including ambient temperature, installation and specific conditions of use. However, los 3/0AWG Hollins Cable URD suelen tener una capacidad de corriente bastante alta debido a su grosor y diseño.
The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..