350-350-350-4/0 Slippery Rock Aluminio XLPE URD Cuádruplex Cable De Entierro Directo
What is 350-350-350-4/0 Slippery Rock Aluminio XLPE URD Cuádruplex Cable De Entierro Directo?
350-350-350-4/0 Slippery Rock Aluminio XLPE URD Cuádruplex Cable De Entierro Directo es un cable eléctrico subterráneo que también se utiliza como cable de entrada de servicio y para el cableado de circuitos secundarios subterráneos. This cable has four gauge conductors 350. Three of these conductors correspond to the phases of a three-phase system, and the fourth driver, that has yellow stripes, acts as the neutral conductor. It is a medium duty cable, with a temperature rating of 90°C and a voltage rating of 600 volts.
350-350-350-4/0 cable de aluminio urd de Slippery Rock XLPE, 350-350-350-4/0 cable de entierro directo de Slippery Rock urd XLPE, 350-350-350-4/0 cable cuádruplex de Slippery Rock XLPE, 350-350-350-4/0 cable cuádruplex de Slippery Rock XLPE, 350-350-350-4/0 cable de cuatro conductores de Slippery Rock XLPE, 350-350-350-4/0 cable de cuatro conductores de Slippery Rock XLPE, 350-350-350-4/0 cable eléctrico de entierro directo de Slippery Rock XLPE, 350-350-350-4/0 cable de alimentación de entierro directo de Slippery Rock XLPE, 350-350-350-4/0 cable de enterramiento directo de aluminio Slippery Rock XLPE.
Standard of 350-350-350-4/0 Slippery Rock Aluminio XLPE URD Cuádruplex Cable De Entierro Directo
ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W
Technical data 350-350-350-4/0 Slippery Rock Aluminio XLPE URD Cuádruplex Cable De Entierro Directo
Phase Conductor Size MCM 350
Phase Conductor Stranding 37
Phase Conductor Insulation Thickness 95 Mls
Base Neutral Messenger Size AWG 4/0
Base Neutral Strand 18
Diameter Single Phase Conductor (Mils) 831
Diameter Complete Cable (O.D.) (Mils) 2006
Weight Per 1000ft Total (Lbs.) 1544
Allowable Ampacity 90C (Amps) 385
Allowable Ampacity In Ducts (Amps) 305
URD Cable Applications
350-350-350-4/0 Slippery Cable URD tiene una capacidad de corriente nominal que depende de varios factores, including ambient temperature, installation and specific conditions of use. However, los 350-350-350-4/0 Slippery suelen tener una capacidad de corriente bastante alta debido a su grosor y diseño.
The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..