500-500-350 Rider Aluminum XLPE URD Triplex Direct Burial Cable

Triplex URD Cable

Contact Us

500-500-350 Rider Aluminum XLPE URD Triplex Direct Burial Cable

What is 500-500-350 Rider Aluminio XLPE URD Triplex Cable De Entierro Directo?

500-500-350 Rider Aluminum XLPE URD Triplex Direct Burial Cable It is intended for use in secondary distribution circuits, being suitable for installation in conduits or for direct burial applications. Maximum operating temperature should not exceed 90°C in wet and dry locations. The nominal voltage is 600 volts. As an option, This cable can be delivered pre-installed in conduit.

Also know as: cable urd de aluminio con conductor 500-500-350 XLPE, cable urd con conductor 500-500-350 XLPE, cable de tres conductores con conductor 500-500-350 XLPE, cable triplex con conductor 500-500-350 XLPE, 500-500-350 cable triplex jinete XLPE, cable subterráneo de aluminio triplex jinete 500-500-350 XLPE, power cord 3 conductores jinete 500-500-350 XLPE, triplex de aluminio jinete 500-500-350 XLPE, triplex subterráneo jinete 500-500-350 XLPE, jinete 500-500-350 cable subterráneo triplex XLPE, jinete 500-500-350 cable triplex subterráneo XLPE, jinete 500-500-350 triplex de entierro directo XLPE, conductor triplex de jinete 500-500-350 XLPE, cable eléctrico de entierro directo jinete 500-500-350 XLPE, jinete 500-500-350 Cable de alimentación de enterramiento directo XLPE, cable de enterramiento directo de aluminio 500-500-350 XLPE.

Standard of 500-500-350 Rider Aluminum XLPE URD Triplex Direct Burial Cable

ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W

Technical data 500-500-350 Rider Aluminum XLPE URD Triplex Direct Burial Cable

Phase conductor size: 500 MCM
Hilo conductor: 37
Neutral conductor size: 350 MCM
Hilo conductor: 37
Insulation thickness: 0,095 inches
External diameter: 1.785 inches
Allowable ampacity: direct burial: 495 amperes to 90 °C
Allowable ampacity in duct: 395 amperes to 90 °C
Weight: 1.563 pounds per foot

URD Cable Applications

500-500-350 Rider Cable URD tiene una capacidad de corriente nominal que depende de varios factores, including ambient temperature, installation and specific conditions of use. However, los 500-500-350 Rider cable suelen tener una capacidad de corriente bastante alta debido a su grosor y diseño.

The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations.