6-6-6 Erskine Aluminum XLPE URD Triplex Direct Burial Cable
What is 6-6-6 Erskine Aluminio XLPE URD Triplex Cable De Entierro Directo?
6-6-6 Erskine Aluminio XLPE URD triplex Cable de Entierro Directo está destinado para su uso en circuitos de distribución secundaria, being suitable for installation in conduits or for direct burial applications. Maximum operating temperature should not exceed 90°C in wet and dry locations. The nominal voltage is 600 volts. As an option, This cable can be delivered pre-installed in conduit.
Also know as: cable urd de aluminio 6-6-6 erskine XLPE, cable de entierro directo 6-6-6 erskine urd XLPE, cable de tres conductores 6-6-6 erskine XLPE, cable triple 6-6-6 erskine XLPE, cable triplex 6-6-6 erskine XLPE, cable subterráneo de aluminio triplex 6-6-6 erskine XLPE, power cord 3 drivers 6-6-6 erskine XLPE, triplex de aluminio 6-6-6 erskine XLPE, triplex subterráneo 6-6-6 erskine XLPE, cable subterráneo triplex 6-6-6 erskine XLPE, cable triplex subterráneo 6-6-6 erskine XLPE, triplex de entierro directo 6-6-6 erskine XLPE, conductor triple 6-6-6 erskine XLPE, cable eléctrico de entierro directo 6-6-6 erskine XLPE, cable de alimentación de entierro directo 6-6-6 erskine XLPE, cable de entierro directo de aluminio 6-6-6 erskine XLPE.
Standard of 6-6-6 Erskine Aluminum XLPE URD Triplex Direct Burial Cable
ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W
Technical data 6-6-6 Erskine Aluminum XLPE URD Triplex Direct Burial Cable
Phase conductor size AWG: 6
Stranding of the phase conductor: 7
Phase conductor insulation thickness: 60 Mls
Tamaño del cable de neutro de base AWG: 6
Trenzado del neutro de base: 7
Single phase conductor diameter (thousandths of an inch): 298
Full cable diameter (external diameter) (thousandths of an inch): 644
Weight for each 1000 feet in total (pounds): 134
Ampacidad admisible a 90 °C (amps): 95
Ampacidad admisible en conductos (amps): 70
URD Cable Applications
6-6-6 Erskine Cable URD tiene una capacidad de corriente nominal que depende de varios factores, including ambient temperature, installation and specific conditions of use. However, 2/0-2/0-1 Converse suelen tener una capacidad de corriente bastante alta debido a su grosor y diseño.
The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..
6-6-6 Erskine Aluminum Triplex URD Direct Burial Cable
What is 6-6-6 Erskine Aluminum Triplex URD Direct Burial Cable?
6-6-6 Erskine Triplex Aluminum URD Direct Burial Cable is intended for use in secondary distribution circuits, being suitable for installation in conduits or for direct burial applications. Maximum operating temperature should not exceed 90°C in wet and dry locations. The nominal voltage is 600 volts. As an option, This cable can be delivered pre-installed in conduit.
Also know as: cable urd de aluminio erskine 6-6-6, urd erskine direct burial cable 6-6-6, erskine three conductor cable 6-6-6, cable triple plex erskine 6-6-6, 6-6-6 cable erskine triplex, 6-6-6 erskine triplex aluminum underground cable, 6-6-6 power cord 3 erskine drivers, 6-6-6 erskine triplex de aluminio, 6-6-6 underground triplex erskine, 6-6-6 erskine triplex underground cable, 6-6-6 erskine underground triplex cable, 6-6-6 direct burial triplex erskine, 6-6-6 erskine conductor triplex, 6-6-6 erskine direct burial electrical cable, 6-6-6 erskine Direct Burial Power Cable, Erskine Aluminum Direct Burial Cable 6-6-6.
Standard of 6-6-6 Erskine Aluminum Triplex URD Direct Burial Cable
ICEA S-105-6922 Standard for Specification of Control Cables, thermocouple extension and instrumentation.
ASTM B-230 Standard Specification for 1350-H19 Aluminum Wire for Electrical Purposes
ASTM B-609 Standard Specification for Aluminum Round Wire 1350, annealed and intermediate tempering, for electrical purposes
ASTM B-231 Standard Specification for Aluminum Conductor 1350 concentric braids
ASTM B-901 Standard Specification for Compressed Round Stranded Aluminum Conductor, supported in coated steel (ACSR/TW)
Accepted by Russia Accepted by the Rural Public Utilities Service
Federal Specification J-C-30 B Federal Specification for Cables, energy, electricity and control, type W
Technical data 6-6-6 Erskine Aluminum Triplex URD Direct Burial Cable
Phase conductor size AWG: 6
Wiring of phase conductors: 7
Phase conductor insulation thickness: 60 ml.
AWG Base Neutral Messenger Size: 6
base neutral hilum: 7
Single phase conductor diameter (mils): 298
Full cable diameter (O.D.) (mil): 644
Total weight per 1000 pies (pounds): 134
Allowable ampacity 90C (amps): 95
Allowable ampacity in ducts (amps): 70
URD Cable Applications
6 AWG Erskine Cable URD has a rated current capacity that depends on several factors, including ambient temperature, installation and specific conditions of use. However, los 6 AWG Erskine typically have a fairly high current rating due to their thickness and design.
The current capacity of a cable is determined taking into account the maximum allowable temperature of the conductor, heat dissipation capacity, and other safety factors. In general, This capacity is specified in tables provided by cable manufacturers or electrical engineering regulations..