NYCY Cable
What is NYCY Cable?
NYCY Drivers:
Material: normally solid or stranded bare copper conductors according to DIN VDE 0295 cl.1/cl.2, BS 6360 cl.1/cl.2, IEC 60228 cl.1/cl.2, etc.
Shape: can be round or fan shaped, depending on the specific model.
Isolation:
Material: PVC insulation, belonging to the DIV4 category, according to HD standard 603.1.
The insulation is designed to ensure that the cable has good electrical properties and mechanical strength.
Armor:
Material: copper wire and copper tape shielding.
Deck:
Material: PVC outer cover, belonging to the DMV5 category, also following the HD standard 603.1.
The cover is usually black and protects the internal structure of the cable.
Nominal voltage:
Nominal voltage: 0,6/1,0 kV para U0/U, suitable for low voltage power transmission.
Test voltage: normally 4000 V to ensure the safety and reliability of the cable at high voltage.
Operating temperature:
Mobile installation: -5°C a +70°C.
Fixed installation: -40°C a +70°C (the upper temperature limit for fixed installations is +70°C in some publications, but it is important to take into account temperature variations in specific application scenarios).
Warp radio:
Cables unipolares: normally 15 times the outer diameter of the cable.
Cables multifilares: normally 12 times the outer diameter of the cable to ensure that the cable is not damaged during bending.
Fireproofing:
Compliant with IEC standard 60332-1-2, which indicates that the cable has a certain ability to self-extinguish when burning, reducing the risk of fire.
Insulation resistance:
Superior a 100 MΩ x km, which ensures that the cable has good insulation properties.
NYCY Cable Construction
VDE 0276-603: It is the standard for fixed power and control cables established by the German Association of Electrical Engineers (VDE), Which NYCY cables fit.
HD 603: German industrial standard related to VDE 0276-603, which specifies in detail the electrical and mechanical properties of cables.
IEC 60332-1-2: Standard of the International Electrotechnical Commission (the) on the fire resistance of cables; NYCY cables meet the fire resistance requirements of this standard.
RoHS: EU Directive on restrictions on the use of certain dangerous substances in electrical and electronic equipment, NYCY cables meet the requirements of this directive.
CE Certification: indicates that the cable meets health requirements, security and environment within the European Economic Area (EEE), NYCY cables are CE certified.
NYCY Cable Construction
STRAIN | NYCY 0.6/1kV |
CONDUCTOR | Class 1 Solid Copper and Class 2 Copper stranded Copper |
ISOLATION | PVC (polyvinyl chloride) |
BINDING TAPE | PVC (polyvinyl chloride) |
CONCENTRIC CONDUCTOR | Copper wires and tape |
OUTER FLOOR | PVC (polyvinyl chloride) |
NYCY cable technical parameters
Number of conductors and mm² per conductor | External diameter [mm] | Copper index (kg/km) | Weight (kg/km) |
2 x 1,5 re/1,5 | 14 | 52 | 245 |
3 x 1,5 re/1,5 | 14 | 66 | 280 |
4 x 1,5 re/1,5 | 15 | 81 | 302 |
7 x 1,5 re/2,5 | 17 | 133 | 450 |
12 x 1,5 re/2,5 | 20 | 205 | 580 |
24 x 1,5 re/6 | 26 | 413 | 1100 |
3 x 2,5 re/2,5 | 15 | 104 | 316 |
4 x 2,5 re/2,5 | 16 | 128 | 360 |
7 x 2,5 re/2,5 | 18 | 200 | 530 |
16 x 2,5 re/6 | 23 | 451 | 950 |
4 x 4 re/4 | 18 | 200 | 485 |
4 x 6 re/6 | 19 | 297 | 616 |
2 x 2,5 re/2,5 | 12.6 | 80 | 241 |
3 x 4 re/4 | 15.3 | 161 | 384 |
3 x 6 re/6 | 16.7 | 240 | 484 |
7 x 4 re/4 | 18.7 | 315 | 621 |
NYCY Cable Application Areas
1. Industrial systems: NYCY cables are widely used in all types of industrial systems, providing stable power transmission and signal control to meet the high requirements of industrial production.
2. Power plants: In power plants, NYCY cables are used as important power transmission and distribution components to ensure stable power production and distribution.
3. Domestic junction box: It is suitable for electrical wiring inside the house, providing a safe and reliable electrical connection and guaranteeing the comfort and safety of domestic electrical consumption.
4. Street lighting: as a power transmission line for public lighting, NYCY cable ensures stable operation of street lights and other lighting installations, and add sparkle to the night city landscape.
5. Powering low voltage systems: NYCY cables can be used as distribution cables for low voltage systems, providing power support for various low voltage equipment.
6. Switchgear control: in switchgear, NYCY cables are used as control cables, transmitting control signals and measuring readings to ensure normal operation of equipment.
7. Mechanical protection: In applications where greater electrical and mechanical protection is required, NYCY cables provide good protection against damage caused to cables by external mechanical forces.
NYCY Cable Installation Environment and Conditions
Indoor and outdoor: NYCY cables are suitable for both indoor and outdoor environments, including a wide range of installation conditions, like outdoors, underground, in concrete and in cable ducts.
Weather resistance: Thanks to its weather resistance, NYCY cable can be used for a long time in outdoor environments and is not easily damaged by bad weather.
Temperature range: NYCY cables can be used in a wide range of operating temperatures, from -5°C to +70°C for mobile installations and from -20°C to +70°C for fixed installations.
NYCY cable manufacturer
Dosense Cable, a renowned brand with 30 years of experience in the sector, is a professional NYCY cables manufacturer and supplier. We are specialized in the production and development of high quality cables, and NYCY cables, as one of our main products, They are widely used in a variety of industrial systems, power plants and home wiring, etc. Dosense Cable is committed to providing our customers with excellent products and services to meet power transmission needs in a variety of complex environments.. Choosing Dosense Cable is choosing reliability and trust.