ТАКСР-ТАКСР(АВ)-ТАКСР(ТВ)-HTLS Conductor Sale Price

ТАКСР

TACSR Conductor - ТАКСР(АВ) - HTLS-проводник

TACSR Conductor-Thermal Resistant Aluminum Conductor Steel Reinforced Conductor

TACSR conductors, or Thermal Resistant Aluminum Conductor Steel Reinforced (ТАКСР) conductors, are designed similarly to conventional ACSR conductors but with Hard Drawn Aluminum wires made from a Heat Resistant Aluminum Alloy (known as TAL). These conductors can operate safely at temperatures above 150℃, allowing for higher current transmission. They are particularly useful in areas like urban centers, coastal regions, or humid environments where there are constraints on building new power transmission corridors. The use of Zirconium-doped aluminum alloy ensures these conductors maintain their electrical and mechanical properties even at elevated temperatures, making them a cost-effective solution for upgrading existing power lines to handle greater capacity.

ТАКСР (/АВ) conductors are employed in overhead electric power transmission lines in urban centers, coastal regions, and humid areas.

We are TACSR, ТАКСР(АВ),ТАКСР(ТВ) manufacturer and factory, мы продаем низкую цену с хорошим качеством.

Data Sheet TACSR Conductor

Размер проводника

(мм2)

Stranding (Nos./mm)

Min. Breaking Load

(кгс)

Reference

Площадь поперечного сечения (мм2)

Overall Diameter (мм)

Масса (кг/км)

ОКРУГ КОЛУМБИЯ

Resistance at 20℃ (Ох/км)

Modulus of Elasticity (kgf/mm2)

Коэффициент линейного расширения

(10-6/℃)

Standard Length

(м)

Текущая пропускная способность (А)

TAl

ST

TAl

ST

Общий

TAl

ST

TAl

ST

Общий

58

6/3.5

1/3.5

1,980

57.73

9.621

67.35

10.5

3.5

158.1

75.04

233.1

0.505

8,400

18.9

1,000

343

80

6/4.2

1/4.2

2,770

83.10

13.85

96.95

12.6

4.2

227.5

108.0

335.5

0.350

8,400

18.9

1,000

430

95

6/4.5

1/4.5

3,810

95.40

15.90

111.3

13.5

4.5

261.2

124.0

385.2

0.306

8,400

18.9

1,000

478

80

15/2.6

4/2.6

4,720

79.64

21.24

100.9

13.0

7.8

219.2

166.5

385.7

0.368

9,390

17.6

2,000

448

100

15/2.9

4/2.9

5,580

99.08

26.42

125.5

14.5

8.7

272.8

207.1

479.9

0.296

9,390

17.6

2,000

517

120

15/3.2

4/3.2

5,550

120.6

32.17

152.8

16.0

9.6

332.2

252.2

584.4

0.243

9,390

17.6

2,000

590

120

30/2.3

7/2.3

5,540

124.7

29.09

153.8

16.1

6.9

345.7

228.0

573.7

0.237

9,080

18.0

2,000

598

160

30/2.6

7/2.6

6,980

159.3

37.16

196.5

18.2

7.8

441.5

291.3

732.8

0.185

9,080

18.0

2,000

706

200

30/2.9

7/2.9

8,640

198.2

46.24

244.4

20.3

8.7

549.3

362.4

911.7

0.149

9,080

18.0

2,000

816

240

30/3.2

7/3.2

10,210

241.3

56.29

297.6

22.4

9.6

668.9

441.3

1,110

0.122

9,080

18.0

2,000

932

330

26/4.0

7/3.1

10,950

326.8

52.84

379.6

25.3

9.3

905.4

414.2

1,320

0.0904

8,360

19.0

2,000

1,128

410

26/4.5

7/3.5

13,910

413.4

67.35

480.8

28.5

10.5

1,145

527.9

1,673

0.0714

8,360

19.0

2,000

1,322

480

45/3.7

7/2.47

11,260

483.8

33.54

517.34

29.6

7.41

1336.1

262.9

1,599

0.0610

7,250

20.8

2,000

1,425

520

54/3.5

7/3.5

15,600

519.5

67.35

586.9

31.5

10.5

1,441

527.9

1,969

0.0569

7,990

19.5

1,600

1,504

610

54/3.8

7/3.8

18,350

612.4

79.38

691.8

34.2

11.4

1,698

622.2

2,320

0.0481

7,990

19.5

1,600

1,682

680

54/4.0

7/4.0

19,810

678.8

87.99

766.8

36.0

12.0

1,882

689.8

2,572

0.0436

7,990

19.5

1,600

1,797

680

45/4.4

7/2.9

15,580

684.5

46.24

730.7

35.1

8.7

1,898

362.4

2,260

0.0431

7,250

20.8

1,600

1,787

810

45/4.8

7/3.2

18,480

814.5

56.29

870.8

38.4

9.6

2,259

441.3

2,700

0.0363

7,250

20.8

1,600

2,004

1,160

84/4.2

7/4.2

27,830

1.163

96.95

1,260

46.2

12.6

3,236

759.8

3,996

0.0254

7,430

20.5

1,200

2,573

1,520

84/4.8

7/4.8

36,390

1.520

126.7

1,647

52.8

14.4

4,228

993.3

5,222

0.0195

7,430

20.5

1,200

3,035

Data Sheet TACSR/AW (20.3% Conductivity AW)

Размер проводника

(мм2)

Stranding (Nos./mm)

Min. Breaking Load

(кгс)

Reference

Площадь поперечного сечения (мм2)

Overall Diameter (мм)

Масса

(кг/км)

ОКРУГ КОЛУМБИЯ

Resistance at 20℃ (Ох/км)

Modulus of Elasticity (kgf/mm2)

Коэффициент линейного расширения

(10-6/℃)

Standard Length

(м)

Текущая пропускная способность (А)

TAl

АВ

TAl

АВ

TAl

АВ

120

30/2.3

7/2.3

5,540

124.7

29.08

16.1

6.9

536.5

0.219

8,100

19.2

2,000

624

160

30/2.6

7/2.6

6,980

159.3

37.16

18.2

7.8

685.4

0.171

8,100

19.2

2,000

734

200

30/2.9

7/2.9

8,640

198.2

46.24

20.3

8.7

852.8

0.138

8,100

19.2

2,000

847

210

30/3.2

7/3.2

10,160

241.3

56.29

22.4

9.6

1,038

0.113

8,100

19.2

2,000

968

330

26/4.0

7/3.1

11,200

326.8

52.84

25.3

9.3

1,252

0.0856

7,620

20.0

2,000

1,159

410

26/4.5

7/3.5

14,230

413.4

67.35

28.5

10.5

1,587

0.0676

7,630

20.0

2,000

1,358

480

45/3.7

7/2.47

11,260

483.84

33.54

29.6

7.4

1,561

0.0595

6,910

21.5

2,000

1,437

520

54/3.5

7/3.5

15,920

519.5

67.35

31.5

10.5

1,883

0.0544

7,390

20.4

1,600

1,537

610

54/3.8

7/3.8

18,730

612.4

79.38

34.2

11.4

2,219

0.0461

7,330

20.4

1,600

1,717

680

45/4.4

7/2.9

15,580

684.5

46.24

35.1

8.7

2,201

0.0422

6,900

21.5

1,600

1,805

810

45/4.8

7/3.2

18,730

814.5

56.29

38.4

9.6

2,628

0.0354

6,910

21.5

1,600

2,028

950

84/3.8

7/3.8

23,780

952.6

79.38

41.8

11.4

3,170

0.0302

7,030

21.2

1,200

2,292

1,160

84/4.2

7/4.2

28,720

1,163

96.95

46.2

12.6

3,872

0.0247

7,030

21.2

1,200

2,606

1,520

84/4.8

7/4.8

37,520

1,520

126.7

52.8

14.4

5,060

0.0189

7,030

21.2

1,200

3,075

Date Sheet TACSR/AW (23% Conductivity AW)

Размер проводника

(мм2)

Stranding (Nos./mm)

Min. Breaking Load

(кгс)

Reference

Площадь поперечного сечения (мм2)

Overall Diameter (мм)

Масса

(кг/км)

ОКРУГ КОЛУМБИЯ

Resistance at 20℃ (Ох/км)

Modulus of Elasticity (kgf/mm2)

Коэффициент линейного расширения

(10-6/℃)

Standard Length

(м)

Текущая пропускная способность (А)

TAl

АВ

TAl

АВ

TAl

АВ

120

30/2.3

7/2.3

7/2.3

124.7

29.08

16.1

6.9

528.9

0.217

7,980

19.4

2,000

625

160

30/2.6

7/2.6

7/2.6

159.3

37.16

18.2

7.8

675.7

0.170

7,980

19.4

2,000

736

200

30/2.9

7/2.9

7/2.9

198.2

46.24

20.3

8.7

840.7

0.136

7,980

19.4

2,000

854

210

30/3.2

7/3.2

7/3.2

241.3

56.29

22.4

9.6

1,024

0.112

7,980

19.4

2,000

973

330

26/4.0

7/3.1

7/3.1

326.8

52.84

25.3

9.3

1,238

0.085

7,540

20.2

2,000

1,163

410

26/4.5

7/3.5

7/3.5

413.4

67.35

28.5

10.5

1,570

0.0671

7,550

20.2

2,000

1,363

480

45/3.7

7/2.47

7/2.47

483.84

33.54

29.6

7.4

1,550

0.0592

6,880

20.6

2,000

1,441

520

54/3.5

7/3.5

7/3.5

519.5

67.35

31.5

10.5

1,865

0.0541

7,330

20.6

1,600

1,541

610

54/3.8

7/3.8

7/3.8

612.4

79.38

34.2

11.4

2,198

0.0458

7,320

20.6

1,600

1,722

680

45/4.4

7/2.9

7/2.9

684.5

46.24

35.1

8.7

2,189

0.0420

6,860

21.6

1,600

1,809

810

45/4.8

7/3.2

7/3.2

814.5

56.29

38.4

9.6

2,613

0.0353

6,880

21.6

1,600

2,031

950

84/3.8

7/3.8

7/3.8

952.6

79.38

41.8

11.4

3,149

0.0300

6,980

21.3

1,200

2,299

1,160

84/4.2

7/4.2

7/4.2

1,163

96.95

46.2

12.6

3,847

0.0246

6,980

21.3

1,200

2,611

1,520

84/4.8

7/4.8

7/4.8

1,520

126.7

52.8

14.4

5,027

0.0189

6,980

21.3

1,200

3,075

Data Sheet TACSR Conductor

PROPERTIES

ТАКСР (ACSR MOOSE EQUIVALENT

ТАКСР (ACSR ZEBRA EQUIVALENT)

ТАКСР (ACSR PANTHER EQUIVALENT)

Typical factors

3.53 мм

0.1378 в

3.18 мм

0.1252 в

3.00 мм

0.1181 в

Reference specifications

МЭК 62004

МЭК 62004

МЭК 62004

Total cross section area

596.99 мм2

0.9253 in2

484.25 мм2

0.7506 in2

261.50 мм2

0.4054 in2

Conductive wire

Al Zr ATI

Al Zr ATI

Al Zr ATI

Core wire

Оцинкованная сталь

Оцинкованная сталь

Оцинкованная сталь

Conductor diameter

31.77 мм

1.2508 в

28.62 мм

1.1268 в

21.00 мм

0.8268 в

Масса

2004

1346.6

1621

1089.3

972

653.2

kg/gm

Ibs/mile

кг/км

Ibs/mile

кг/км

Ibs/mile

Ultimate tensile strength

16438 kg

36239.54 lbs

14407 kg

31761.96 lbs

10119 kg

22308.55 lbs

DC resistance at

0.06

0.09

0.07

0.11

0.14

0.22

20°C temperature

0/km

Q/mile

O/km

Q/mile

n/km

Q/mile

Maximum operating temperature

150°С

302°F

150°С

302°F

150°С

302°F

Current carrying capacity at maximum operating temperature

1509 Amp

1302 Amp

831 Amp

Анимированные иконки социальных сетей к Компания Acurax, занимающаяся адаптивным веб-дизайном