22kV and 35kV AAC ACSR XLPE Overhead Cable for Myanmar
22kV 35kV AAC ACSR XLPE Cable
22kV ACSR-CX, 35kV ACSR-CX
22kV AL-CX, 35kV AL-CX
22kV ACSR-X, 35kV ACSR-X
22kV AL-X, 35kV AL-X
22kV 35kV AAC ACSR XLPE Overhead Cable For Myanmar
Yapı: Tamamı Alüminyum İletken, Alüminyum İletken Çelik Takviyeli (ACSR), featuring stranded aluminum conductors and galvanized steel reinforcement, along with Semi-Conducting Screened Cross-Linked Polyethylene (XLPE) Insulation Power Cable.
Option: The stranded conductor layer shall be filled with water-blocking material.
Başvuru: Suitable for overhead power transmission and distribution lines.

22kV ACSR-CX (BS One 50397-1)
Kondüktör | Thickness of Insulation | Yaklaşık. overall Çap | Yaklaşık. Etraflı Ağırlık | Min.. Breaking Load | Max.D.C. Kondüktör Rezistans(20℃) | |||
Gross Sectional Area | Na.and Diameter of wires(Al) | Na. and Diameter of wires(Steel) | Outside Çap | |||||
mm2 | mm | mm | mm | mm | mm | kg/km | kn | Ω/ km |
50/8 | 6/3.20 | 1/3.20 | 9.6 | 2.5 | 17 | 330 | 17.112 | 0.5951 |
70/11 | 6/3.80 | 1/3.80 | 11.4 | 2.5 | 18 | 430 | 24.13 | 0.4218 |
95/16 | 6/4.50 | 1/4.50 | 13.5 | 2.5 | 20 | 560 | 33.369 | 0.3007 |
120/19 | 26/2.40 | 7/1.85 | 15.15 | 2.5 | 22 | 660 | 41.521 | 0.244 |
150/19 | 24/2.80 | 7/1.85 | 16.75 | 2.5 | 24 | 760 | 46.307 | 0.2046 |
150/24 | 26/2.70 | 7/2.10 | 17.1 | 2.5 | 24 | 810 | 52.279 | 0.2039 |
185/24 | 24/3.15 | 7/2.10 | 18.9 | 2.5 | 26 | 930 | 58.075 | 0.154 |
185/29 | 26/2.98 | 7/2.30 | 18.82 | 2.5 | 26 | 960 | 62.055 | 0.1519 |
240/32 | 24/3.60 | 7/2.40 | 21.6 | 2.5 | 29 | 1180 | 75.05 | 0.1182 |
300/39 | 24/4.00 | 7/2.65 | 23.95 | 2.5 | 31 | 1410 | 90.574 | 0.0958 |
330/43 | 54/2.80 | 7/2.80 | 25.2 | 2.5 | 32 | 1550 | 103.784 | 0.0869 |
400/51 | 54/3.05 | 7/3.05 | 27.5 | 2.5 | 35 | 1810 | 120.481 | 0.0733 |
35kV ACSR-CX (BS One 50397-1)
Kondüktör | Thickness of Yalıtım | Yaklaşık. overall Çap | Yaklaşık. Etraflı Ağırlık | Min.. Breaking Load | Max.D.C. Kondüktör Rezistans(20℃) | |||
Gross Sectional Area | Na.and Diameter of wires(Al) | Na. and Diameter of wires(Steel) | Outside Çap | |||||
mm2 | mm | mm | mm | mm | mm | kg/km | kn | Ω/ km |
50/8 | 6/3.20 | 1/3.20 | 9.6 | 3.9 | 19 | 400 | 17.112 | 0.5951 |
70/11 | 6/3.80 | 1/3.80 | 11.4 | 3.9 | 21 | 510 | 24.13 | 0.4218 |
95/16 | 6/4.50 | 1/4.50 | 13.5 | 3.9 | 23 | 650 | 33.369 | 0.3007 |
120/19 | 26/2.40 | 7/1.85 | 15.15 | 3.9 | 25 | 760 | 41.521 | 0.244 |
150/19 | 24/2.80 | 7/1.85 | 16.75 | 3.9 | 26 | 860 | 46.307 | 0.2046 |
150/24 | 26/2.70 | 7/2.10 | 17.1 | 3.9 | 27 | 910 | 52.279 | 0.2039 |
185/24 | 24/3.15 | 7/2.10 | 18.9 | 3.9 | 29 | 1040 | 58.075 | 0.154 |
185/29 | 26/2.98 | 7/2.30 | 18.82 | 3.9 | 29 | 1070 | 62.055 | 0.1519 |
240/32 | 24/3.60 | 7/2.40 | 21.6 | 3.9 | 31 | 1300 | 75.05 | 0.1182 |
300/39 | 24/4.00 | 7/2.65 | 23.95 | 3.9 | 34 | 1540 | 90.574 | 0.0958 |
330/43 | 54/2.80 | 7/2.80 | 25.2 | 3.9 | 35 | 1690 | 103.784 | 0.0869 |
400/51 | 54/3.05 | 7/3.05 | 27.5 | 3.9 | 37 | 1960 | 120.481 | 0.0733 |
22kV AL-CX (BS One 50397-1)
Kondüktör | Thickness of Yalıtım | Apprax. Etraflı Çap | Approx. Overalal Ağırlık | Min. Breaking Load | Max.D.C. Kondüktör Rezistans(20℃) | ||
Coss Sectional Area | Na. and Diameter of wires | Outside Çap | |||||
mm2 | mm | mm | mm | mm | kg/km | kn | Ω/ km |
25 | 7/2.13 | 6.39 | 2.5 | 13 | 170 | 4.5 | 1.1489 |
35 | 7/2.51 | 753 | 2.5 | 15 | 200 | 5.913 | 0.8347 |
50 | 7/3.00 | 9 | 2.5 | 16 | 260 | 8.198 | 0.5748 |
70 | 7/3.55 | 10.65 | 2.5 | 17 | 330 | 11.288 | 0.4131 |
95 | 7/4.10 | 12.3 | 25 | 19 | 410 | 14.784 | 0.3114 |
120 | 19/2.80 | 14 | 2.5 | 21 | 500 | 19.89 | 0.2459 |
150 | 19/3.15 | 15.75 | 2.5 | 23 | 600 | 24.42 | 0.1944 |
185 | 19/3.50 | 17.5 | 25 | 24 | 720 | 29.832 | 0.1574 |
240 | 19/4.00 | 20 | 25 | 27 | 900 | 38.192 | 0.1205 |
300 | 37/3.15 | 22.05 | 2.5 | 29 | 1050 | 47.569 | 0.1 |
400 | 37/3.66 | 25.62 | 2.5 | 33 | 1360 | 63.42 | 0.074 |
35kV AL-CX (BS One 50397-1)
Kondüktör | Yaklaşık dış çap mm | Kurye sürücüsü (EHS) | Yaklaşık ağırlık kg/km | ||||
Damar sayısı x nominal kesit N.° × mm² | Kablo sayısı (dk.) | Nominal iletken çapı mm | Örgü No. × mm | Messenger iletken çapı mm | Minimum kopma yükü kN | ||
3X1X35 | 6 | 6.9 | 54.1 | 7×3,00 | 9 | 64.36 | 2337 |
3X1X50 | 6 | 8.1 | 67.9 | 7×2,64 | 7.92 | 49.82 | 3208 |
3X1X70 | 12 | 9.8 | 71.5 | 7×2,64 | 7.92 | 49.82 | 3577 |
3X1X95 | 15 | 11.4 | 75.4 | 7×3.68 | 11.04 | 92.82 | 4339 |
3X1X120 | 15 | 12.8 | 78.4 | 7×3.68 | 11.04 | 92.82 | 4703 |
3X1X150 | 15 | 14.4 | 82.3 | 19×2.86 | 14.29 | 149.9 | 5571 |
3X1X185 | 30 | 16 | 86.2 | 19×2.86 | 14.29 | 149.9 | 6093 |
3X1X240 | 30 | 18.4 | 91.3 | 19×2.86 | 14.29 | 149.9 | 6854 |
22kV ACSR-X (BS One 50397-1)
Kondüktör | Thickness of Yalıtım | Yaklaşık. overall Çap | Yaklaşık. Etraflı Ağırlık | Min.. Breaking Load | Max.D.C. Kondüktör Rezistans(20℃) | |||
Gross Sectional Area | Na.and Diameter of wires(Al) | Na. and Diameter of wires(Steel) | Outside Çap | |||||
mm2 | mm | mm | mm | mm | mm | kg/km | kn | Ω/ km |
50/8 | 6/3.20 | 1/3.20 | 9.6 | 3.5 | 17 | 340 | 17.112 | 0.5951 |
70/11 | 6/3.80 | 1/3.80 | 11.4 | 3.5 | 19 | 440 | 24.13 | 0.4218 |
95/16 | 6/4.50 | 1/4.50 | 13.5 | 3.5 | 21 | 570 | 33.369 | 0.3007 |
120/19 | 26/2.40 | 7/1.85 | 15.15 | 3.5 | 23 | 680 | 41.521 | 0.244 |
150/19 | 24/2.80 | 7/1.85 | 16.75 | 3.5 | 24 | 780 | 46.307 | 0.2046 |
150/24 | 26/2.70 | 7/2.10 | 17.1 | 3.5 | 25 | 830 | 52.279 | 0.2039 |
185/24 | 24/3.15 | 7/2.10 | 18.9 | 3.5 | 26 | 950 | 58.075 | 0.154 |
185/29 | 26/2.98 | 7/2.30 | 18.82 | 3.5 | 26 | 970 | 62.055 | 0.1519 |
240/32 | 24/3.60 | 7/2.40 | 21.6 | 3.5 | 29 | 1195 | 75.05 | 0.1182 |
300/39 | 24/4.00 | 7/2.65 | 23.95 | 3.5 | 32 | 1430 | 90.574 | 0.0958 |
330/43 | 54/2.80 | 7/2.80 | 25.2 | 3.5 | 33 | 1570 | 103.784 | 0.0869 |
400/51 | 54/3.05 | 7/3.05 | 27.5 | 3.5 | 35.1 | 1830 | 120.481 | 0.0733 |
35kV ACSR-X (BS One 50397-1)
Kondüktör | Thickness of Yalıtım | Yaklaşık. overall Çap | Yaklaşık. Etraflı Ağırlık | Min.. Breaking Load | Max.D.C. Kondüktör Rezistans(20℃) | |||
Gross Sectional Area | Na.and Diameter of wires(Al) | Na. and Diameter of wires(Steel) | Outside Çap | |||||
mm2 | mm | mm | mm | mm | mm | kg/km | kn | Ω/ km |
50/8 | 6/3.20 | 1/3.20 | 9.6 | 55 | 21 | 450 | 17.112 | 0.5951 |
70/11 | 6/3.80 | 1/3.80 | 11.4 | 55 | 23 | 560 | 24.13 | 0.4218 |
95/16 | 6/4.50 | 1/4.50 | 13.5 | 55 | 25 | 710 | 33.369 | 0.3007 |
120/19 | 26/2.40 | 7/1.85 | 15.15 | 55 | 27 | 820 | 41.521 | 0.244 |
150/19 | 24/2.80 | 7/1.85 | 16.75 | 55 | 28 | 930 | 46.307 | 0.2046 |
150/24 | 26/2.70 | 7/2.10 | 17.1 | 55 | 29 | 980 | 52.279 | 0.2039 |
185/24 | 24/3.15 | 7/2.10 | 18.9 | 5.5 | 30 | 1110 | 58.075 | 0.154 |
185/29 | 26/2.98 | 7/2.30 | 18.82 | 55 | 30 | 1130 | 62.055 | 0.1519 |
240/32 | 24/3.60 | 7/2.40 | 21.6 | 5.5 | 33 | 1370 | 75.05 | 0.1182 |
300/39 | 24/4.00 | 7/2.65 | 23.95 | 55 | 36 | 1630 | 90.574 | 0.0958 |
330/43 | 54/2.80 | 7/2.80 | 25.2 | 55 | 37 | 1770 | 103.784 | 0.0869 |
400/51 | 54/3.05 | 7/3.05 | 27.5 | 55 | 39 | 2050 | 120.481 | 0.0733 |
22kV AL-X (BS One 50397-1)
Kondüktör | Thickness of Yalıtım | Yaklaşık. Etraflı Çap | Yaklaşık. Etraflı Ağırlık | Min.. Breaking Load | Max.D.C Kondüktör Rezistans(20°C | ||
Coss Sectional Area | Na. and Diameter of wires | Outside Diameter | |||||
mm2 | mm | mm | mm | mm | kg/km | kn | Ω/ km |
25 | 7/2.13 | 6.39 | 3.5 | 14 | 180 | 4.5 | 1.1489 |
35 | 7/2.51 | 7.53 | 3.5 | 15 | 220 | 5.913 | 0.8347 |
50 | 7/3.00 | 9 | 3.5 | 16 | 270 | 8.198 | 0.5748 |
70 | 7/3.55 | 10.65 | 3.5 | 18 | 350 | 11.288 | 0.4131 |
95 | 7/4.10 | 12.3 | 3.5 | 20 | 430 | 14.784 | 0.3114 |
120 | 19/2.80 | 14 | 3.5 | 22 | 510 | 19.89 | 0.2459 |
150 | 19/3.15 | 15.75 | 3.5 | 23 | 620 | 24.42 | 0.1944 |
185 | 19/3.50 | 17.5 | 3.5 | 25 | 730 | 29.832 | 0.1574 |
240 | 19/4.00 | 20 | 3.5 | 28 | 910 | 38.192 | 0.1205 |
300 | 37/3.15 | 22.05 | 3.5 | 30 | 1075 | 47.569 | 0.1 |
400 | 37/3.66 | 25.62 | 3.5 | 33 | 1390 | 63.42 | 0.074 |
35kV AL-X (BS One 50397-1)
Kondüktör | Thickness of Yalıtım | Yaklaşık. Etraflı Çap | Yaklaşık. Etraflı Ağırlık | Min.. Breaking Load | Max.D.C Kondüktör Rezistans(20℃) | ||
Cross Sectional Area | Na. and Diameter of wires | Outside Çap | |||||
mm2 | mm | mm | mm | mm | kg/km | kn | Ω/ km |
25 | 7/2.13 | 6.39 | 5.5 | 18 | 272 | 4.5 | 1.1489 |
35 | 7/2.51 | 7.53 | 5.5 | 19 | 317 | 5.913 | 0.8347 |
50 | 7/3.00 | 9 | 5.5 | 21 | 382 | 8.198 | 0.5748 |
70 | 7/3.55 | 10.65 | 5.5 | 22 | 463 | 11.288 | 0.4131 |
95 | 7/4.10 | 12.3 | 5.5 | 24 | 554 | 14.784 | 0.3114 |
120 | 19/2.80 | 14 | 5.5 | 26 | 651 | 19.89 | 0.2459 |
150 | 19/3.15 | 15.75 | 5.5 | 27 | 765 | 24.42 | 0.1944 |
185 | 19/3.50 | 17.5 | 5.5 | 29 | 889 | 29.832 | 0.1574 |
240 | 19/4.00 | 20 | 5.5 | 32 | 1084 | 38.192 | 0.1205 |
300 | 37/3.15 | 22.05 | 5.5 | 34 | 1258 | 47.569 | 0.1 |
400 | 37/3.66 | 25.62 | 5.5 | 37 | 1595 | 63.42 | 0.074 |
22kV and 35kV AAC ACSR XLPE Overhead Cable for Myanmar
22kV 35kV AAC ACSR XLPE
Power grids: To transmit electrical power from power generation plants to substations and then to distribution networks, cable could be used in underground or overhead installations.
Industrial applications: In factories, mines, and other industrial settings, the cable could be used to connect electrical equipment, motors, transformatörler, and other components within the facility’s power distribution system.
Infrastructure projects: For large-scale infrastructure projects such as airports, tüneller, bridges, and road networks, cable can be specified for its durability, waterproofing, ve çevresel faktörlere karşı dayanıklılık.
Renewable energy systems: In wind farms, solar farms, and other renewable energy generation facilities, the cable could be used to connect turbines, panels, and other power generating units to the main power grid.
Utility networks: Utilities, including water, gas, and electric utilities, often use specialized cables in their networks. The cable could be tailored to specific requirements within these networks, such as increased fire resistance, low smoke emission, or resistance to chemicals and other environmental hazards.
Marine and Offshore Installations: Due to its potential impermeability and resistance to saltwater corrosion, the cable could be suitable for use in marine and offshore environments, such as connecting offshore wind turbines, submarine cables, or subsea power distribution systems.
It is important to note that the exact specifications and capacities of the cable will depend on the manufacturer and the specific application requirements. Always consult the manufacturer’s technical documentation and specifications before selecting and using the cable.